The FA 180 ZM-1 type filter has been developed to protect soldiers and military equipment from nuclear, biological, and chemical contamination, as well as dust. The FA 180 ZM-1 is used in various protective facilities, including mobile command posts, military camps, and medical centers. The most important features of the system include easy and quick start-up, highest reliability, and the ability to operate continuously (24/7) for extended periods.
System Features:
The FA 180 ZM-1 type filter creates overpressure inside the tent/chamber and prevents the penetration of contaminated and dusty air. This solution eliminates the need to wear gas masks and protective clothing inside the chamber.
The system has a highly efficient filter preceded by a dust filter, which reduces the blocking of subsequent levels of nuclear, biological, and chemical filtration. This ensures maximum efficiency for a longer time, even in harsh environments and in high dust conditions.
Filter cartridges protecting against nuclear, biological, and chemical contamination provide enormous benefits and outperform standard filters currently available on the market.
The level of sensitivity to moisture has been reduced to a minimum, ensuring extremely long life and excellent absorption capabilities for toxic industrial chemicals.
These features make the FA 180 ZM-1 essential for the need to apply effective preventive measures to soldiers conducting operations in international areas.
Main advantages:
Technical data of the FA 180 ZM-1 filter:
| Product code: Filtering system:
Housing: |
B 70089
B 61011 |
| Air flow in filtering mode (with filter protecting against nuclear, biological and chemical contamination)
Air flow in filtering mode (with fine dust filter) |
180 or 360 (106 or 212) m3/h
260 or 520 (153 or 306) m3/h |
| Overpressure inside the chamber in filtering mode (factory settings) | 200-400 Pa |
| Rated voltage | 230 V AC |
| Rated frequency | 50 Hz |
| Cyclonic separation degree according to the test using Arizona dust (Arizona course) | > 98% |
| Pre-filter separation degree (EN 779) | 95 % |
| Total weight (without filters)
Filtering system Housing |
85 kg
50 kg 35 kg |